Upcoming System Maintenance

Notice: Promega will be performing essential system updates January 21–25.

Order processing and shipping will pause starting January 21 at 4:00 PM CST and resume on January 26.
Please plan to order in advance for any products needed during this timeframe.

Please contact Customer Service with any questions.

W6010_Lumit-Human-IL-1beta-Immunoassay_3 W6011_Lumit-Human-IL-1beta-Immunoassay_3 W6012_Lumit-Human-IL-1beta-Immunoassay_3 W7010_Lumit-Mouse-IL-1beta-Immunoassay_3 W7011_Lumit-Mouse-IL-1beta-Immunoassay_3 W7012_Lumit-Mouse-IL-1beta-Immunoassay_3 w116a-c-lumit-human-il-1beta-standard w119a-c-lumit-mouse-il-1beta-standard

No-Wash Immunoassay for IL-1β Detection in Cells

  • Fast add-and-read protocol performed directly on cells
  • Luminescent detection with just a standard plate-reading luminometer
  • Scalable to 96- or 384- well plates, protocols included
  • Pack sizes show assay number for 96-well plates

Catalog Number:

Choose a product

Size

Catalog Number: W6010

Please Enquire

Add W6010 to Helix

Catalog Number: W6011

Please Enquire

Add W6011 to Helix

Catalog Number: W6012

Please Enquire

Add W6012 to Helix

Catalog Number: W7010

Please Enquire

Add W7010 to Helix

Catalog Number: W7011

Please Enquire

Add W7011 to Helix

Catalog Number: W7012

Please Enquire

Add W7012 to Helix

Catalog Number: W116A-C

Please Enquire

Catalog Number: W119A-C

Please Enquire


Request a Sample
Not available in all countries

Overview
Protocols
Specifications
Resources
Related Products

Quantificare l'attivazione dell'inflammasoma senza noiose fasi di lavaggio

Il Lumit™ IL-1β Immunoassay misura quantitativamente l'IL-1β rilasciata in campioni di colture cellulari utilizzando un protocollo semplice e senza lavaggio. È sufficiente aggiungere gli anticorpi marcati al campione, aggiungere il reagente di rilevazione e leggere il segnale luminescente utilizzando un luminometro standard a lettura di piastra. L'intero protocollo viene completato in meno di 70 minuti! Il test può essere utilizzato direttamente sulle cellule in coltura o sul terreno di coltura trasferito in una piastra di analisi separata.

Come funziona il Lumit™ IL-1β Immunoassay

Gli anticorpi primari contro l'IL-1β sono stati selezionati per il loro rilevamento specifico e sensibile e sono stati marcati con le subunità LgBiT e SmBiT della NanoBiT® Luciferase. In presenza di IL-1β, le subunità si uniscono per formare un enzima luciferasi attivo. L'aggiunta di un substrato ottimizzato genera un segnale luminescente proporzionale ai livelli di IL-1β.
16522ma

Protocollo semplice a una piastra, senza fasi di lavaggio!

16545ma

Ampia gamma dinamica di rilevamento Lumit™

L'intervallo lineare da picomolare a nanomolare del Lumit™ copre le concentrazioni previste per la maggior parte dei modelli cellulari.

Linear range of lumit IL-1b human immunoassay
Linear range of lumit IL-1b mouse immunoassay

Test

IL-1β (umano) Immunoassay

IL-1β (Topo) Immunodosaggio

Limite di rilevamento (LOD)

10pg/ml (3 SD sopra il fondo)

8pg/ml (3 SD sopra il fondo)

Intervallo dinamico

22pg/ml – 40ng/ml

11pg/ml – 20ng/ml

Dose minima rilevabile (MDD)

7pg/ml (2 SD sopra il fondo)

5pg/ml (2 SD sopra il fondo)

Tempo di analisi

70 minuti

Tipo di campione

Surnatanti di colture cellulari

SD=Deviazione Standard

Screening ad alto rendimento di inibitori dell'inflammasoma NLRP3

Il formato add-and-read del Lumit™ IL-1β Immunoassay consente uno screening ad alto rendimento per i modulatori del rilascio di IL-1β.
IL-1b inhibitor high throughput screening

L'inibitore dell'inflammasoma NLRP3, MCC950, impedisce l'attivazione della caspasi-1 e il rilascio di IL-1 maturaβ. Una titolazione di MCC950 è stata aggiunta a cellule THP-1 differenziate (5 ×104/pozzetto) seguite da LPS (20 EU/ml) o da un veicolo. L'immunodosaggio Lumit™ IL-1β (Human) è stato eseguito dopo 5 ore.

This peer-reviewed study "Interrogating direct NLRP3 engagement and functional inflammasome inhibition using cellular assays" examines the direct engagement and functionality of NLRP3 pathway activity in cells using several mechanistic assays, including the Lumit® IL-1β Immunoassay and Caspase-Glo 1 Inflammasome Assay.

nlrp3-martha-obrien-paper

Esplora altri test di rilevamento delle citochine

Offriamo un portfolio of assays to detect cytokines  crescente di campioni di colture cellulari.

Non riuscite a’trovare il vostro target nell'elenco?

Please enquire per l'accesso anticipato ai nuovi saggi in fase di sviluppo.

Per una biotecnologia che sa che il tempo ha un valore significativo, gli immunodosaggi Lumit™ sono un modo essenziale per raccogliere rapidamente dati affidabili in modo da poter giungere a conclusioni e prendere decisioni in tempi brevi.

Jonathan Chow, scienziato principale, Corner Therapeutics

Specifications

Catalog Number:

What's in the box

Item Part # Choose a size Concentration

Lumit® Detection Substrate B

VB405A 1 × 160μl

Lumit® Detection Buffer B

VB406A 1 × 3.2ml

Human IL-1β Standard

W116A 1 × 25μl 10μg/ml

Anti hIL-1β mAb-SmBiT, 1000X

W117A 1 × 15μl

Anti hIL-1β mAb-LgBiT, 1000X

W118A 1 × 15μl

Certificate of Analysis

Search by lot number

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

BB

Please see the Protocol for detailed storage conditions.

Patents and Disclaimers

U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.

U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.

What's in the box

Item Part # Choose a size Concentration

Lumit® Detection Substrate B

VB405B 1 × 1.25ml

Lumit® Detection Buffer B

VB406B 1 × 25ml

Human IL-1β Standard

W116A 1 × 25μl 10μg/ml

Anti hIL-1β mAb-SmBiT, 1000X

W117B 1 × 150μl

Anti hIL-1β mAb-LgBiT, 1000X

W118B 1 × 150μl

Certificate of Analysis

Search by lot number

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

BB

Please see the Protocol for detailed storage conditions.

Patents and Disclaimers

U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.

U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.

What's in the box

Item Part # Choose a size Concentration

Lumit® Detection Substrate B

VB405A 5 × 160μl

Lumit® Detection Buffer B

VB406A 5 × 3.2ml

Human IL-1β Standard

W116A 1 × 25μl 10μg/ml

Anti hIL-1β mAb-SmBiT, 1000X

W117A 5 × 15μl

Anti hIL-1β mAb-LgBiT, 1000X

W118A 5 × 15μl

Certificate of Analysis

Search by lot number

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

BB

Please see the Protocol for detailed storage conditions.

Patents and Disclaimers

U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.

U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.

What's in the box

Item Part # Choose a size Concentration

Lumit® Detection Substrate B

VB405A 1 × 160μl

Lumit® Detection Buffer B

VB406A 1 × 3.2ml

Mouse IL-1β Standard

W119A 1 × 25μl 10μg/ml

Anti mIL-1β mAb-SmBiT, 1000X

W120A 1 × 15μl

Anti mIL-1β mAb-LgBiT, 1000X

W121A 1 × 15μl

Certificate of Analysis

Search by lot number

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

BB

Please see the Protocol for detailed storage conditions.

Patents and Disclaimers

U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.

U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.

What's in the box

Item Part # Choose a size Concentration

Lumit® Detection Substrate B

VB405B 1 × 1.25ml

Lumit® Detection Buffer B

VB406B 1 × 25ml

Mouse IL-1β Standard

W119A 1 × 25μl 10μg/ml

Anti mIL-1β mAb-SmBiT, 1000X

W120B 1 × 150μl

Anti mIL-1β mAb-LgBiT, 1000X

W121B 1 × 150μl

Certificate of Analysis

Search by lot number

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

BB

Please see the Protocol for detailed storage conditions.

Patents and Disclaimers

U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.

U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.

What's in the box

Item Part # Choose a size Concentration

Lumit® Detection Substrate B

VB405A 5 × 160μl

Lumit® Detection Buffer B

VB406A 5 × 3.2ml

Mouse IL-1β Standard

W119A 1 × 25μl 10μg/ml

Anti mIL-1β mAb-SmBiT, 1000X

W120A 5 × 15μl

Anti mIL-1β mAb-LgBiT, 1000X

W121A 5 × 15μl

Certificate of Analysis

Search by lot number

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

BB

Please see the Protocol for detailed storage conditions.

Patents and Disclaimers

U.S. Pat. Nos. 9,797,889, 9,797,890, 10,107,800 and 11,493,504; European Pat. No. 2970412; Japanese Pat. Nos. 7280842 and 7532562; and other patents and patents pending.

U.S. Pat. No. 8,809,529, European Pat. No. 2635582, Japanese Pat. No. 5889910 and other patents and patents pending.

What's in the box

Item Part # Choose a size Concentration

Human IL-1β Standard

W116A 1 × 25μl 10μg/ml

Certificate of Analysis

Search by lot number

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

BB

Please see the Protocol for detailed storage conditions.

What's in the box

Item Part # Choose a size Concentration

Mouse IL-1β Standard

W119A 1 × 25μl 10μg/ml

Certificate of Analysis

Search by lot number

Use Restrictions

For Research Use Only. Not for Use in Diagnostic Procedures.

Storage Conditions

BB

Please see the Protocol for detailed storage conditions.