CellTiter-Glo® 2.0 Cell Viability Assay
A Luminescent Cell Viability Assay for Fast, Easy, Everyday Use
- ATP assay for detection of viable cells
- Reduced preparation time and convenient repeat use over multiple days
- Same great performance as classic CellTiter-Glo® Cell Viability Assay
- Integrates with the MyGlo® Reagent Reader
Catalog Number:
Choose a product
Size
Catalog Number: G9241
Catalog Number: G9242
Catalog Number: G9243
Catalog Number: MG1010
CellTiter-Glo® 2.0 misura l'ATP, un indicatore chiave della salute delle cellule
CellTiter-Glo® 2.0, basato sulla chimica originale del CellTiter-Glo® Cell Viability Assay, è un saggio a singolo reagente con una stabilità migliorata per una comoda conservazione e un'impostazione più semplice. Sia che si eseguano saggi di proliferazione cellulare in una singola piastra o che si analizzino centinaia di piastre alla volta, il reagente pronto all'uso è stato progettato per un uso quotidiano rapido e semplice. È un test ATP altamente sensibile con un'ampia linearità, adatto a screening ad alta produttività e ad applicazioni multiplex.
Il saggio CellTiter-Glo® 2.0 determina il numero di cellule vitali nella coltura quantificando l'ATP, che indica la presenza di cellule metabolicamente attive. La lettura della luminescenza è direttamente proporzionale al numero di cellule vitali in coltura.
Semplicità di impostazione del saggio e maggiore stabilità
Un singolo reagente pronto all'uso e un semplice protocollo "aggiungi-mescola-misura" consentono di non dover miscelare i componenti.
Il reagente CellTiter-Glo® 2.0 è stabile a temperatura ambiente e a 4°C, consentendo un'implementazione rapida e semplice del test ed eliminando lo scongelamento e la miscelazione richiesti da altri test ATP. La maggiore stabilità consente inoltre una comoda conservazione.
| Percentuale di attività residua | Stabilità del reagente CellTiter-Glo® 2.0 | Stabilità del reagente CellTiter-Glo® "Originale |
|---|---|---|
| >85 ctività a 22°C | 7 giorni | 12 ore |
| >85 ctivity a 4°C | 2 mesi | 3,5 giorni |
Prestazioni del test
Il saggio di vitalità cellulare CellTiter-Glo® 2.0 presenta le stesse elevate prestazioni del saggio CellTiter-Glo® classico, rendendolo adatto all'uso da banco fino allo screening ad alta produttività.
Alta sensibilità e ampia linearità. La luminescenza misurata con il saggio CellTiter-Glo® 2.0 è proporzionale al numero di cellule Jurkat vitali in coltura su tre ordini di grandezza in piastre da 96, 384 e 1536 pozzetti.
High sensitivity of the assay system enables reliable performance even from low cell densities. Jurkat cells were seeded in all-white 96-well plates at 400, 2,000 and 10,000 cells/well and were treated with Bortezomib for 20 hours. Viability was measured with CellTiter-Glo® 2.0 and MyGlo® Reagent Reader
Multiplex con altri test di vitalità cellulare o citotossicità
Il saggio di vitalità cellulare CellTiter-Glo® 2.0 può essere multiplexato con altri saggi, riducendo i costi della coltura cellulare e il lavoro. Il multiplexing dei saggi nello stesso pozzetto di campionamento consente di ottenere misure complementari della salute delle cellule per correggere gli errori di coltura, di piastratura o le interferenze della chimica del saggio.
Nell'esempio qui riportato, il reagente per il test di citotossicità CellTox™ Green è stato aggiunto alle cellule K562 trattate con bortezemib dopo 48 ore di esposizione. È stata misurata la fluorescenza associata alla citotossicità. È stato aggiunto il reagente per il saggio CellTiter-Glo® 2.0 e misurata la luminescenza come indicatore della proliferazione cellulare.
Case Study
Automated Assay Workflow for Mitochondrial Dysfunction
Challenge:
Louise Young, a research fellow at the University of Strathclyde, studies mitochondria’s role in Alzheimer’s and cancer. Her team needed a reliable, reproducible method to measure ROS output while screening compounds to decrease ROS levels. Traditional assays had wash steps, causing variability.
Result:
Using ROS-Glo™ H2O2 Assay, the team achieved faster turnaround with a no-wash protocol, greater reproducibility through luminescent readout and improved efficiency for quicker data collection.
Their workflow also includes RealTime-Glo™ Annexin V Assay for apoptosis/necrosis and CellTiter-Glo® 2.0 Assay for cell viability. Several compounds successfully reduced ROS, guiding future research into their protein targets.
Bioluminescence Resource Center
Learn more about how luminescence works, what makes it different from fluorescence and how you can use luminescence to fuel your own research.
Protocols
Specifications
Catalog Number:
What's in the box
| Item | Part # | Choose a size |
|---|---|---|
CellTiter-Glo® 2.0 Reagent |
G924A | 1 × 10ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
What's in the box
| Item | Part # | Choose a size |
|---|---|---|
CellTiter-Glo® 2.0 Reagent |
G924B | 1 × 100ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
What's in the box
| Item | Part # | Choose a size |
|---|---|---|
CellTiter-Glo® 2.0 Reagent |
G924C | 1 × 500ml |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
What's in the box
| Item | Part # | Choose a size | Available Separately |
|---|---|---|---|
MyGlo™ Reagent Reader
|
MG1000 | 1 × 1 each | |
CellTiter-Glo® 2.0 Reagent |
G9241 | 1 × 10ml | View Product |
SDS
Search for SDSCertificate of Analysis
Use Restrictions
For Research Use Only. Not for Use in Diagnostic Procedures.Storage Conditions
See Protocol for detailed storage recommendations.Resources
Articles
Citations
-
Effective photo-enhancement of cellular activity of fluorophore-octaarginine antisense PNA conjugates correlates with singlet oxygen formation, endosomal escape and chromophore lipophilicity.
2018
Sci. Rep.
-- -
DUX4-induced dsRNA and MYC mRNA stabilization activate apoptotic pathways in human cell models of facioscapulohumeral dystrophy.
2018
PLoS Genet.
-- -
miR-195 targets cyclin D3 and survivin to modulate the tumorigenesis of non-small cell lung cancer.
2018
Cell Death Dis.
-- -
Glucose starvation induces LKB1-AMPK-mediated MMP-9 expression in cancer cells.
2018
Sci. Rep.
-- -
Traditional and systems biology based drug discovery for the rare tumor syndrome neurofibromatosis type 2.
2018
PLos ONE
-- -
Sensitivity and engineered resistance of myeloid leukemia cells to BRD9 inhibition.
2016
Nat Chem. Biol.
-- -
The cellular stress proteins CHCHD10 and MNRR1 (CHCHD2): Partners in mitochondrial and nuclear function and dysfunction
2018
J. Biol. Chem.
-- -
NRF2 Regulates HER1 Signaling Pathway to Modulate the Sensitivity of Ovarian Cancer Cells to Lapatinib and Erlotinib.
2017
Oxid. Med. Cell Longev.
-- -
Gas6-Axl signaling in presence of Sunitinib is enhanced, diversified and sustained in renal tumor cells, resulting in tumor-progressive advantages.
2017
Exp. Cell Res.
-- -
Imaging oxygen in neural cell and tissue models by means of anionic cell-permeable phosphorescent nanoparticles.
2015
Cell Molec. Life Sci.
-- -
Development and validation of a luminescence-base, medium throughput assay for drug screening in Schistosoma mansoni.
2015
PLOS Negl. Trop. Dis.
-- -
In vitro ischemia decreases histone H4K16 acetylation in neural cells.
2015
FEBS Lett.
-- -
Glutamine drives glutathione synthesis and contributes to radiation sensitivity of A549 and H460 lung cancer cell lines.
2016
Biochim. Biophys. Acta
-- - See all citations
Related Products
Similar Products
Test di vitalità cellulare CellTiter-Glo® 3D
Un metodo omogeneo ottimizzato per valutare la vitalità in colture cellulari 3D.
G9681, G9682, G9683
Test di vitalità cellulare RealTime-Glo™ MT
Un metodo bioluminescente per monitorare cineticamente la vitalità in coltura cellulare fino a 72 ore.
G9711, G9712, G9713
Test di vitalità cellulare CellTiter-Fluor
Un test di vitalità cellulare non litico e fluorescente con capacità multipla.
G6080, G6081, G6082
Lumit® hKi-67 Immunoassay for Cell Proliferation
Easy add-mix-measure plate-based assay for tracking Ki-67 without washing steps or specialized detection equipment.
CS3076A01
Frequently Used With
GloMax® Discover System
High-performance microplate reader for detecting luminescence, fluorescence and absorbance.
GM3000
Test di citotossicità CellTox™ Green
Misura i cambiamenti nell'integrità della membrana. Monitora cineticamente la citotossicità fino a 72 ore con capacità multiplex.
G8741, G8742, G8743, G8731
Test RealTime-Glo™ di apoptosi e necrosi
Un test in un'unica fase, basato su piastra, per il monitoraggio continuo della progressione dell'apoptosi.
JA1011, JA1012, JA1000, JA1001
Sistema di analisi Caspase-Glo® 3/7
Un test luminescente su piastra di facile utilizzo per la rilevazione dell'attività della caspasi-3/7.
G8090, G8091, G8093, G8092, MG1010
Product Citations
Recent publications that mention the use of this product.